A-2Y(L)2Y Outdoor Telecommunication Cable
According To DIN VDE 0816 Part 1
Reference Standard: A-2Y(L)2Y according to DIN VDE 0816 Part 1
Application:This cable is used as distribution duct or direct buired telephone cable.
Conductor Material: Solid annealed copper conductor
Insulation Material:PE
Laying-up: Star quads in unit stranding
Wrapping Polyester Tape
Screen Material: Aluminium Foil with copper drain wire
Sheath Material: PE
Sheath Color: Black
Temperature Range: Flexible: -20¡æ to +50¡æ fixed installation:- 40¡ã C to + 70¡ãC
Operating Voltage: 150V to 225V
Electrical Performance:
Conductor Diameter (mm) |
Insulation Resistance of per km at 20 o C
Min. (GOhms) |
Conductor Resistance per km loop
Max. (Ohms) |
0.40 |
5 |
300 |
0.60 |
5 |
130 |
0.80 |
5 |
73.2 |
Size & Dimensions:
A - 2Y(L)2Y ... x 2 x 0,6 STIII BD
Part No. |
No.of pairs |
Outerdiameter
£¨mm£© |
Cable Weight
£¨kg/km£© |
Copper Weight
(kg/km) |
CCL-TC-2Y6P0.6 |
6 |
11.5 |
130 |
34 |
CCL-TC-2Y10P0.6 |
10 |
13.5 |
180 |
57 |
CCL-TC-2Y20P0.6 |
20 |
16.0 |
275 |
113 |
CCL-TC-2Y30P0.6 |
30 |
18.0 |
365 |
170 |
CCL-TC-2Y40P0.6 |
40 |
20.5 |
450 |
226 |
CCL-TC-2Y50P0.6 |
50 |
21.5 |
535 |
283 |
CCL-TC-2Y70P0.6 |
70 |
25.5 |
715 |
396 |
CCL-TC-2Y100P0.6 |
100 |
28.0 |
970 |
565 |
CCL-TC-2Y150P0.6 |
150 |
32.5 |
1374 |
848 |
CCL-TC-2Y2006P0.6 |
200 |
37.0 |
1795 |
1131 |
A - 2Y(L)2Y ... x 2 x 0.8 STIII BD
Part No. |
No.of pairs |
Outer diameter
£¨mm£© |
Cable Weight
£¨kg/km£© |
Copper Weight
(kg/km) |
CCL-TC-2Y6P0.8 |
6 |
13.0 |
175 |
60 |
CCL-TC-2Y10P08 |
10 |
15 |
245 |
101 |
CCL-TC-2Y20P0.8 |
20 |
18.5 |
400 |
201 |
CCL-TC-2Y30P0.8 |
30 |
21.0 |
550 |
302 |
CCL-TC-2Y40P0.8 |
40 |
23.0 |
660 |
402 |
CCL-TC-2Y50P0.8 |
50 |
26.0 |
860 |
503 |
CCL-TC-2Y70P0.8 |
70 |
29.0 |
1140 |
704 |
CCL-TC-2Y100P0.8 |
100 |
34.0 |
1580 |
1005 |
CCL-TC-2Y150P0.8 |
150 |
41.5 |
2265 |
1508 |
CCL-TC-2Y2006P0.8 |
200 |
47.0 |
3000 |
2011 |
|